KOREAN BATTERY CELL SOURCING
LG 21700-M52VT catalog visualization

AI-assisted catalog visualization for model presentation. Request actual lot photographs.

LG ENERGY SOLUTION · 21700 Series

LG 21700-M52VT

21700 energy cell with a specified field-use voltage window

Energy reference18.73Wh nominal

The filename says V2, but the document itself identifies Rev. 1, dated 2023-12-19, and is marked non-final. M52VT is kept separate from M52V. Field-use cycling uses 4.1–2.85V in the supplied specification.

Discuss this model on WhatsApp ↗

For OEMs, battery pack manufacturers and industrial buyers.

MODEL OVERVIEW

LG 21700-M52VT — Selection & Sourcing

LG 21700-M52VT is a 21700 cylindrical lithium-ion cell. The supplied document lists 18.73Wh nominal. The filename says V2, but the document itself identifies Rev. 1, dated 2023-12-19, and is marked non-final. M52VT is kept separate from M52V. Field-use cycling uses 4.1–2.85V in the supplied specification.

For pack qualification, review the charge profile, continuous and peak load, mechanical clearances, protective circuitry and cell temperatures against the exact specification. A similar cylindrical format does not make different cell models interchangeable.

For a model-specific quotation, provide your sample and production quantities, delivery destination and required documentation. Source reference: 2023-LSD-MBD-b00042, INR21700M52VT, Rev. 1, 2023-12-19, pages 5–9. Document contents take precedence over the V2 filename.

TECHNICAL REFERENCE

Specifications & Operating Conditions

Read each value with its test conditions. Confirm the applicable document revision before design approval.

Model / catalog codeLG 21700-M52VT
Cell format21700 Series
Nominal energy18.73Wh; charge 1.5A to 4.20V / 50mA termination, discharge 1A to 2.50V at 25°C
Minimum energy18.34Wh under the same energy measurement conditions
Nominal voltage3.69V
C-rate reference1C = 5000mA; this is a test-current basis, not a guaranteed rated capacity
Energy measurement voltage window4.20–2.50V
Usable field-cycle voltage window4.10–2.85V; source sections 2.4, 2.6 and 4.2.4
Maximum charge current by ambient temperature1500mA at 0–25°C; 3500mA at 25–45°C
Maximum discharge current by ambient temperature2500mA at −20–10°C; 15000mA at 10–25°C; 7500mA at 25–55°C; observe temperature and voltage limits
Operating temperature (ambient)Charge: 0–45°C; discharge: −20–55°C
BMU cell-surface temperature limitsBelow 50°C during charge and 70°C during discharge
DimensionsDiameter ≤21.44mm; height ≤71.00mm
Weight67.7 ± 1.0g, tubed cell
Cycle life — field-use window≥86% initial energy at 500 cycles; charge 1.5A to 4.1V / 250mA termination; discharge 2.5A to 2.85V; 25°C; rest 10min / 20min
Cycle life — additional laboratory test≥75% initial energy at 500 cycles; charge 2.5A to 4.2V / 250mA termination; discharge 5A to 2.5V; 25°C; rest 10min / 20min. Not a replacement for the specified field-use voltage window.
Charge termination noteSection 4.1.1 uses 250mA; energy measurement sections 2.1 / 4.1.3 use 50mA. Match the termination condition to the stated measurement.
Specification basis

Technical reference: 2023-LSD-MBD-b00042, INR21700M52VT, Rev. 1, 2023-12-19, pages 5–9. Document contents take precedence over the V2 filename. Confirm the applicable revision and offered lot before design approval. The supplied source is summarized here; it is not offered as a public PDF download.

APPLICATION REVIEW

What to Check for Your Pack

OEM battery pack evaluation

For these project types, compare usable energy at the working load, cell-holder tolerances, busbar design and the temperature-dependent operating limits.

  • Energy and load: usable energy, continuous current, peak duration and charging opportunities.
  • Mechanical and thermal fit: the exact drawing, connections, enclosure temperature and cooling arrangement.
  • Qualification: a test plan based on the finished equipment, including its protection settings and required approvals.

PROCUREMENT DOCUMENTS

Datasheet, Traceability & Certificates

Ask for the specification and drawing that match the offered lot. If your project needs a UN 38.3 test summary, SDS or a particular cell certificate, include that requirement in the enquiry.

BUYER QUESTIONS

Before You Order

Is this cell suitable for my application?

For these project types, compare usable energy at the working load, cell-holder tolerances, busbar design and the temperature-dependent operating limits. Application names on this page are evaluation starting points, not a claim that an OEM has approved this exact cell.

Can I get the LG 21700-M52VT datasheet?

Yes—send the complete model code and your project requirements. We will review the matching specification and available documentation with you. Any preliminary values should be confirmed before production approval.

What are the wholesale price, MOQ and lead time?

These are quoted for the requested model, quantity, available lot and destination. Send sample demand and expected production volume so the offer can address your schedule.

Which documents should accompany the order?